Sonatest Masterscan D-70

$3,980

Category:

Description

descriptions

The Masterscan D-70 offers the inspector a fully capable and functional set of tools and software for inspection across all applicated. Constructed using impact resistant materials and designed to meet IP67 standards, the D-70 offers excellent water resistance. The D-70 has a color transflective VGA display, providing high visibility in any lighting condition, with the enhanced user interface and a full screen A-Scan display is available at the touch of a button. Features can be added and new upgrades performed in the working environment, reducing downtime and increasing work flexibility. High levels of near surface resolution, penetrating power (450V pulser – square and spike) and excellent signal to noise ration are key functions of the Masterscan D-70. Capabilities include Encoded B-Scan, Advanced Thickness logging and Dryscan capability in a portable enclosure.

Features
  • Configurable on-board software
  • Customizable & intuitive menus
  • Split DAC / DVG(AVG)
  • Angle Measurement Mode
  • Dryscan Capability
  • Field Upgradeable
  • Encoded B-Scan
  • A-Scan Fade
  • 4GB on-board memory
  • USB Interface for PC import / export
specifications
Test Range: 0.04″ – 787″ (0-1mm up to 0-20,000mm) in steel at 5930m/s (19455f/s)
Velocity: 256 – 16,000 m/s continuously variable
Probe: 0 to 1000 μs
Delay: 800″ (0-20,000m) in steel at 5930m/s.
Gain: 0 to 110dB adjustable in 0.1, 0.5, 1, 2, 6, 14 and 20dB steps.
Test Modes: Pulse echo and transmit/receive. Single Crystal, Double Crystal and Pitch-Catch.
Damping: 50 and 400 ohm damping selectable.
Pulser: 100-450V – ve spike and square wave. Pulse Width from 30nS to 2500nS. Rise/Fall times <5nS into 50R load.
P.R.F: Adjustable 5Hz to 6kHz. External sync also available.
Screen Update Rate: 60Hz
Rectification: RF, Full wave, +ve half-wave and -ve half-wave
Frequency Range: 8 selectable filter bands.

  1. 100kHz – 500kHz
  2. 200kHz – 800kHz
  3. 0.4MHz – 1.6MHz
  4. 1.4MHz – 3.0MHz
  5. 3.0MHz – 8.0MHz
  6. 7.0MHz – 15.0MHz
  7. 9.0MHz – 21.0MHz
  8. 1.6MHz – 33.0MHz (Wideband)
  9. Additional tuned low frequency pre-amp with Dryscan option.
System Linearity: Vertical = 0.5% Full Screen Height (FSH). Horizontal +/- 0.2% Trace Full Screen Width (FSW).
Reject (Selectable): Up to 80% Linear reject (removes baseline noise without affecting indication amplitude)
Or
Up to 50% Suppressive reject (increase zero offset and reduces amplitude of all echoes)
LED Warning when active.
Units: Inch (in), Metric (mm) or microseconds
Display: Color Transflective VGA (640 x 480) TFT
Display area: 116.16 x 87.2 mm (4.57 x 3.43 in).
A-Scan Area: 400 x 510 pixels (normal), 460 x 620 (FS).
Colors: 9 color options with variable brightness.
Gate Monitor: Two independent gates for measurement and monitoring. Start and width fully adjustable over the entire range of the instrument. Levels adjustable from 0% to 100%, positive or negative triggering on each gate with audible & visual alarms. Gate resolution is 5nS.
Zoom: Expands range and delay to cover the area set by Gate 1 start & width controls.
AGC: Automatic Gain Control automatically sets the signal in Gate 1 to a level between 10% and 90% FSH, tolerance between 5% and 20%.
Measurement Modes:
Mode 1: Signal monitor, Gate alarms can be active but no measurements are displayed.
Mode 2: Depth and amplitude of first signal in gate.
Mode 3: Echo-Echo distance measurements.
Mode 4: Trigonometric display of beam-path, surface distance (including X-offset) and depth of indication from the inspection surface together with echo amplitude. Curved surface correction can be applied for convex and concave surfaces. Half-skip can be indicated on screen.
Mode 5: Gate to Gate distance measurement.
Mode 6: Flank to Flank
Mode 7: Beam Angle, calculated from beam path, hole radius and hole center depth.
Measurement Display: Live display and updates on screen at 3 times per second. Large display of a single measurement available.
Contour: Trailing-Edge slew-rate control to reduce half cycles in rectified modes. Selectable from one of 6 levels.
Waveform Smoothing: Select from:

  1. None (both min and max values are displayed in the A-Scan)
  2. Fill (Min values set to baseline value, produces a solid A-Scan)
  3. Smooth (Min values ignored, produces a clear outline A-Scan)
Persistence: Causes previous A-scans to “fade out” at a user-determined rate.
Auto-Cal: Provides automatic calculation of velocity and probe zero from 2 reference echoes.
Reference Waveform: Displays a previously stored A-log in a color different from the active display: enabling a quick visual check of the differences.
Clock: Built in, battery-backed RTC keeps time and date. Visible on the status line, always stored with Panels, A-logs etc.
Internal Memory: 4 GB storage available for A-scans, panels, T-logs, B-logs etc. 450,000 Panels, 200,000 A-Logs, 300,000 B Charts, 440,000 T-Logs.
Active Peak Memory: Retains all A-scans on screen for echo-dynamic pattern analysis, with the active A-scan displayed in a separate color.
Notes: Alphanumeric labelling for panel stores, A-logs, B-logs etc.
Display Freeze: Hold the current waveform on screen for off-line processing.
Language Support: Multiple languages are selectable from a list including:
English, French, Spanish, Russian, Chinese (Modern). Others are available on request.
Encoder Connection: Lemo min 4-pin connector (D70)
Video Output: Factory Option on D-70.
USB Connection: Internal storage shown as Memory Device.
Transducer Sockets: BNC or LEMO (factory option).
Power: Lithium Ion 14.4V battery pack. Typically 12 hours for D-70. Indication of battery charge status. Recharge time 3-4 hrs. Battery can be charged separately. Mains pack optional.
Charger: 100-240 VAC, 50-60 Hz.
Environmental: Designed to meet IP67
Temperature: Operating: 14° to 131°F (-10° to 55°C)
Storage: -40° to 167°F (-40° to 75°C)
Size: 6.77″ x 9.37″ x 2.75″ (172 x 238 x 70mm) (HxwxD)
Weight: 3.7 lbs. (1.7 kg) with battery
Warranty: 2 year
Extended Warranty: Sonacover – extended 5 year warranty, including 4 calibrations.
Calibration Standards: EN12668-1:2010 (Detailed Specification available on request).
Standards: Vibration to 514.5-5 Proc 1 Annex C Fig 6
Shock 516.5 Proc 1 15g/6ms
Explosive atmospheres – MIL-STD 810G
Method 511.5 Procedure I