Description
Fluke 712B Pressure Calibrator
The Fluke 712B Temperature Calibrator is ideal for the professional that wants a highly accurate, easy-to-use, single function temperature calibrator. Capable of measuring and simulating 13 different RTD types and resistances, and measuring 4 to 20 mA signals while simultaneously sourcing a temperature signal.
The 712B was designed for convenience and functionality on the job site, including a convenient hanging strap designed for use with this model. With dual inputs and a backlit display for easy interpretation of measurements.
Included with the 712B:
Magnetic hanging tool
Batteries
Manual
Traceable Calibration Certificate
Test leads
Specifications
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals
30 V
Operating temperature
-10 ?C to 50 ?C
Storage temperature
-30 ?C to 60 ?C
Operating altitude
2,000 meters
Storage altitude
12,000 meters
Relative humidity (% RH operating without condensation)
Non condensing
90% (10 ?C to 30 ?C)
75% (30 ?C to 40 ?C)
45% (40 ?C to 50 ?C)
(Without condensation)
Vibration requirements
MIL-T-28800E, Class 2
Drop text requirements
1 meter
IP Rating
IEC 60529: IP52
Electromagnetic environment
IEC 61326-1, Portable
Safety
IEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply
4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L)
52.5 mm x 84 mm x 188.5 mm
Weight
515 g
DC mA Measurement
Resolution
0-24 mA
Range
0.001 mA
Accuracy (% of reading + counts)
0.010% + 2 ?A
Temperature coefficient
? (0.002% of reading + 0.002% of range) /?C ( <18 ?C or >28 ?C)
Ohms Measurement
Ohms range
Accuracy (% of reading +counts)
0.00 ? to 400.00 ?
0.015% + 0.05 ?
400.0 ? to 4000.0 ?
0.015% + 0.5 ?
Note: Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 ? (0.00 ?~400.00 ?), 0.2 ? (400.0 ?~4000.0 ?) to the specifications.
Temperature coefficient
? (0.002% of reading + 0.002% of range) /?C ( <18 ?C or >28 ?C)
Ohms Source
Ohms range
1.0 ? to 400.0 ?
1.00 ? to 400.00 ?
400.0 ? to 1500.0 ?
1500.0 ? to 4000.0 ?
Excitation current from measurement device
0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts)
0.015% + 0.1 ?
0.015% + 0.05 ?
0.015% + 0.5 ?
0.015% + 0.5 ?
Resolution
0.00 ? to 400.00 ?
0.01 ?
400.0 ? to 4000.0 ?
0.1 ?
Temperature coefficient
? (0.002% of reading + 0.002% of range) /?C ( <18 ?C or >28 ?C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms
RTD Input and Output
RTD Type (?)
Range (?C)
Measure (?C)
Source (?C)
1-year
2-year
Source current
1-year
2-year
10? Pt(385)
-200 to 100 ?C
1.5 ?C
3 ?C
1 mA
1.5 ?C
3 ?C
100 to 800 ?C
1.8 ?C
3.6 ?C
1 mA
1.8 ?C
3.6 ?C
50? Pt(385)
-200 to 100 ?C
0.4 ?C
0.7 ?C
1 mA
0.4 ?C
0.7 ?C
100 to 800 ?C
0.5 ?C
0.8 ?C
1 mA
0.5 ?C
0.8 ?C
100 ? Pt(385)
-200 to 100 ?C
0.2 ?C
0.4 ?C
1 mA
0.2 ?C
0.4 ?C
100 to 800 ?C
0.015%
+0.18 ?C
0.03%
+0.36 ?C
1 mA
0.015%
+0.18 ?C
0.03%
+0.36 ?C
200 ? Pt(385)
-200 to 100 ?C
0.2 ?C
0.4 ?C
500 ?A
0.2 ?C
0.4 ?C
100 to 630 ?C
0.015%
+0.18 ?C
0.03%
+0.36 ?C
500 ?A
0.015%
+0.18 ?C
0.03%
+0.36 ?C
500 ? Pt(385)
-200 to 100 ?C
0.3 ?C
0.6 ?C
250 ?A
0.3 ?C
0.6 ?C
100 to 630 ?C
0.015%
+0.28 ?C
0.03%
+0.56 ?C
250 ?A
0.015%
+0.28 ?C
0.03%
+0.56 ?C
1000 ? Pt(385)
-200 to 100 ?C
0.2 ?C
0.4 ?C
250 ?A
0.2 ?C
0.4 ?C
100 to 630 ?C
0.015%
+0.18 ?C
0.03%
+0.36 ?C
250 ?A
0.015%
+0.18 ?C
0.03%
+0.36 ?C
100 ? Pt(3916)
-200 to 100 ?C
0.2 ?C
0.4 ?C
1 mA
0.2 ?C
0.4 ?C
100 to 630 ?C
0.015%
+0.18 ?C
0.03%
+0.36 ?C
1 mA
0.015%
+0.18 ?C
0.03%
+0.36 ?C
100 ? Pt(3926)
-200 to 100 ?C
0.2 ?C
0.4 ?C
1 mA
0.2 ?C
0.4 ?C
100 to 630 ?C
0.015%
+0.18 ?C
0.03%
+0.36 ?C
1 mA
0.015%
+0.18 ?C
0.03%
+0.36 ?C
10 ? Cu(427)
-100 to 260 ?C
1.5 ?C
3 ?C
1 mA
1.5 ?C
3 ?C
120 ? Ni(672)
-80 to 260 ?C
0.15 ?C
0.3 ?C
1 mA
0.15 ?C
0.3 ?C
50 ? Cu(427)
-180 to 200 ?C
0.4 ?C
0.7 ?C
1 mA
0.4 ?C
0.7 ?C
100 ? Cu(427)
-180 to 200 ?C
0.2 ?C
0.4 ?C
1 mA
0.2 ?C
0.4 ?C
YSI400
15 to 50 ?C
0.2 ?C
0.4 ?C
250 ?A
0.2 ?C
0.4 ?C
Sensor inaccuracies not included.
Resolution: 0.1 ?C.
Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0 ?C (Pt10 and Cu10), 0.6 ?C (Pt50 and Cu50), 0.4 ?C (Other RTD types) to the specifications.
Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 ?~400.00 ?), 0.05 mA~0.8 mA (400.0 ?~1500.0 ?), 0.05 mA~0.4 mA (1500.0 ? ~4000.0 ?), excitation current (0.25 mA for Pt1000 range).
Temperature Coefficient: ?0.05 ?C /?C for measure, ? 0.05 ?C /?C (<18 ?C or >28 ?C) for source.
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.
Click here for complete specifications on the Fluke 712B
Reviews
There are no reviews yet.