Fluke 435-II Series of Power Quality Analyzers

$4,000

The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the Fluke 435-II better for longer term, higher resolution or more demanding power quality studies. The wide range of measurement functions and measurement methods make it the perfect tool for both power quality troubleshooting and discovering energy savings. Whether you?re checking the performance of motors and generators, trying to discover the source of an intermittent power problem or performing an energy study?this tool gives you the data you need to quickly get to the source of the problem.

SKU: 435-II Category:

Description

Fluke 435-II Three-Phase Power Quality and Energy Analyzer
Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics. Quickly understand the capacity of your existing electrical panels, troubleshoot circuit breaker trips and uncover and monetize energy costs.

$7,999.99 Availability:
1 to 2 Weeks
Add to Cart

Fluke 435-II Basic Power Quality and Energy Analyzer
Help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems. Additionally, the Fluke-patented energy loss algorithm, Unified Power Measurement, measures and quantifies energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.

$7,599.99 Availability:
2 to 3 Weeks
Add to Cart

Fluke 435-II Specifications
Model
Measurement range
Resolution
Accuracy
Volt
Vrms (ac+dc)
435-II
1 V to 1000 V phase to neutral
0.01 V
? 0.1% of nominal voltage****
Vpk

1 Vpk to 1400 Vpk
1 V
5% of nominal voltage
Voltage Crest Factor (CF)

1.0 > 2.8
0.01
? 5 %
Vrms?
435-II

0.1 V
? 0.2% of nominal voltage
Vfund
435-II

0.1 V
? 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc)
i430-Flex 1x
5 A to 6000 A
1 A
? 0.5% ? 5 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
? 0.5% ? 5 counts

1mV/A 1x
5 A to 2000 A
1A
? 0.5% ? 5 counts

1mV/A 10x
0.5 A A to 200 A (ac only)
0.1 A
? 0.5% ? 5 counts
Apk
i430-Flex
8400 Apk
1 Arms
? 5 %

1mV/A
5500 Apk
1 Arms
? 5 %
A Crest Factor (CF)

1 to 10
0.01
? 5 %
Amps?
i430-Flex 1x
5 A to 6000 A
1 A
? 1% ? 10 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
? 1% ? 10 counts

1mV/A 1x
5 A to 2000 A
1A
? 1% ? 10 counts

1mV/A 10x
0.5 A A to 200 A (ac only)
0.1 A
? 1% ? 10 counts
Afund
i430-Flex 1x
5 A to 6000 A
1 A
? 0.5% ? 5 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
? 0.5% ? 5 counts

1mV/A 1x
5 A to 2000 A
1A
? 0.5% ? 5 counts

1mV/A 10x
0.5 A A to 200 A (ac only)
0.1 A
? 0.5% ? 5 counts
Hz
Hz
Fluke 435 @ 50 Hz nominal
42.500 Hz to 57.500 Hz
0.001 Hz
? 0.01 Hz
Fluke 435 @ 60 Hz nominal
51.000 Hz to 69.000 Hz
0.001 Hz
? 0.01 Hz
Power
Watts (VA, var)
i430-Flex
max 6000 MW
0.1 W to 1 MW
? 1% ? 10 counts

1 mV/A
max 2000 MW
0.1 W to 1 MW
? 1% ? 10 counts
Power factor (Cos j/DPF)

0 to 1
0.001
? 0.1% @ nominal load conditions
Energy

kWh (kVAh, kvarh)
i430-Flex 10x
Depends on clamp scaling and V nominal
? 1% ? 10 counts

Energy loss
i430-Flex 10x
Depends on clamp scaling and V nominal
? 1% ? 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n)

DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n)

OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts
%f
0.0 % to 100 %
0.1 %
? 0.1% ? n x 0.1 %

%r
0.0 % to 100 %
0.1 %
? 0.1% ? n x 0.4 %

Absolute
0.0 to 1000 V
0.1 V
? 5% *

THD
0.0 % to 100 %
0.1 %
? 2.5 %
Amps
%f
0.0 % to 100 %
0.1 %
? 0.1% ? n x 0.1%

%r
0.0 % to 100 %
0.1 %
? 0.1% ? n x 0.4 %

Absolute
0.0 to 600 A
0.1 A
? 5% ? 5 counts

THD
0.0 % to 100 %
0.1 %
? 2.5 %
Watts
%f or %r
0.0 % to 100 %
0.1 %
? n x 2%

Absolute
Depends on clamp scaling and V nominal

? 5% ? n x 2 % ? 10 counts

THD
0.0 % to 100 %
0.1 %
? 5 %
Phase Angle

-360? to +0?
1?
? n x 1?
Flicker
Plt, Pst, Pst(1min) Pinst

0.00 to 20.00
0.01
? 5 %
Unbalance
Volts
%
0.0 % to 20.0 %
0.1 %
? 0.1 %
Amps
%
0.0 % to 20.0 %
0.1%
? 1 %
Mains signaling
Threshold levels

Threshold, limits and signaling duration is programable for two signaling frequencies


Signaling frequency

60 Hz to 3000 Hz
0.1 Hz

Relative V%

0 % to 100 %
0.10 %
? 0.4 %
Absolute V3s (3 second avg.)

0.0 V to 1000 V
0.1 V
? 5 % of nominal voltage

General specifications

Case
Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display
Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory
8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clock
Time and date stamp for Trend mode, Transient display, System Monitor and event capture

Environmental

Operating temperature
0 ?C ~ +40 ?C; +40 ?C ~ +50 ?C excl. battery
Storage temperature
-20 ?C ~ +60 ?C
Humidity
+10 ?C ~ +30 ?C: 95% RH non-condensing

+30 ?C ~ +40 ?C: 75% RH non-condensing

+40 ?C ~ +50 ?C: 45% RH non-condensing
Maximum operating altitude
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V

Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V

Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC)
EN 61326 (2005-12) for emission and immunity
Interfaces
mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
Warranty
Three years (parts and labor) on main instrument, one year on accessories
*? 5 % if ? 1 % of nominal voltage ? 0.05 % of nominal voltage if < 1% of nominal voltage

** 50Hz/60Hz nominal frequency according to IEC 61000-4-30

*** 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode.

****for nominal voltage 50 V to 500 V

Click here for complete specifications on the Fluke 435-II

Reviews

There are no reviews yet.

Be the first to review “Fluke 435-II Series of Power Quality Analyzers”

Your email address will not be published. Required fields are marked *