Description
Fluke 3000 FC HVAC System
Key features
The Fluke 3000 FC HVAC System provides measurement of all common electrical parameters
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:
- True-RMS AC clamp meter
- Measure up to 400 AAC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
Specifications: Fluke 3000 FC HVAC System
Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [Number of least significant digits]).
Detailed Specifications | |||||
AC Voltage | |||||
Range ¹ / Resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||||
Accuracy 2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | |||
500 Hz to 1 kHz | 2.0% + 3 | ||||
1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. |
|||||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||||
Function | |||||
mV | Range / Resolution | 600.0 mV / 0.1 mV | |||
Accuracy | 0.09% + 2 | ||||
V | Range / Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
|||
Accuracy | 0.09% + 2 0.15% + 2 |
||||
))) | Range / Resolution | 600 Ω / 1 Ω | |||
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||||
Ω | Range / Resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
|||
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 |
||||
Diode test | Range / Resolution | 2.000 V / 0.001 V | |||
Accuracy | 1% + 2 | ||||
µF | Range / Resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF |
|||
Accuracy | 1.2% + 2 10% typical |
||||
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||||
AC and DC Current | |||||
Function | |||||
mA AC (45 Hz to 1 kHz) |
Range 1 / Resolution | 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA |
|||
Accuracy | 1.5% + 3 | ||||
mA DC 2 | Range 1 / Resolution | 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA |
|||
Accuracy | 0.5% + 3 | ||||
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. |
|||||
Frequency | |||||
Range / Resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||||
Accuracy 1 | 0.1% + 1 | ||||
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||||
Input Characteristics | |||||
Function | Overload protection |
Input impedance (nominal) |
Common mode rejection ratio (1 kΩ unbalance) | Normal mode rejection | |
1100 Vrms | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
1100 Vrms | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
1100 Vrms | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
Open circuit test voltage | Full scale voltage | Typical short circuit current | |||
To 6 MΩ | 50 MΩ | Typical short circuit current | |||
1100 Vrms | < 2.7 VDC | < 0.7 VDC | < 0.9 VDC | < 350 mA | |
1100 Vrms | < 2.7 VDC | 2.000 VDC | < 1.1 mA | ||
mA Function | |||||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||||
MIN/MAX Recording Accuracy | |||||
DC functions | The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration. | ||||
AC functions | The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration. | ||||
General Specifications | |||||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||||
Display (LCD) | Update rate | 4/sec | |||
Volts, amps, ohms | 6000 counts | ||||
Frequency | 10,000 counts | ||||
Capacitance | 1,000 counts | ||||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||||
Battery life | 250 hours minimum | ||||
RF communications | 2.4 GHZ ISM Band | ||||
RF communication range | Open air, unobstructed | Up to 20 m | |||
Obstructed, sheetrock wall | Up to 6.5 m | ||||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5 m | ||||
Temperature | Operating | -10°C to 50°C | |||
Storage | -40°C to 60°C | ||||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) |
||||
Altitude | Operating | 2,000 m | |||
Storage | 12,000 m | ||||
Electromagnetic compatibility EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
||||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
||||
Certifications | CSA, FCC, CE | ||||
Ingress Protection (IP) rating | IP54 | ||||
Pollution Degree | 2 | ||||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||||
Weight | 340 g (12 oz) | ||||
Warranty | Three years | ||||
Not compatible with Fluke CNX test tools |
Fluke a3000 FC Wireless AC Current Clamp Module
Specifications | ||
Range | 0.5 A to 400.0 A | |
Resolution | 0.1 A | |
Accuracy | 400.0 A: 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100 Hz to 500 Hz) | |
Inrush | Max displayed reading | 999.9A |
Crest factor (50 Hz / 60 Hz) | 3 at 500 A 2.5 at 600 A 1.42 at 1000 A add 2% for C.F. > 2 |
|
LCD w/ backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C |
|
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2 | |
Safety rating | CAT III 600 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP30 | |
Pollution Degree | 2 | |
Jaw opening | 34 mm (1.33 in) | |
Size (H x W x D) | 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications | ||||
Range K-Type | -200°C to 1372°C | |||
Resolution | 0.1°C | |||
Accuracy | ±[0.5% + 0.3°C] counts | |||
Input terminals | K-type mini | |||
LCD w/backlight | 3 ½ digits | |||
Log rate/interval | 1 sec minimum/adjustable by PC | |||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
Battery life | 400 hours | |||
Memory | Record up to 65,000 readings | |||
RF communications | 2.4 GHZ ISM Band | |||
RF communication range | Open air, unobstructed | Up to 20 m | ||
Obstructed, sheetrock wall | Up to 6.5 m | |||
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
Operating temperature | -10°C to +50°C | |||
Storage temperature | -40°C to +60°C | |||
Temperature coefficient | 0.01% of reading +0.03°C per°C | |||
Temperature scale | ITS-90 | |||
Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
Altitude | Operating | 2,000 m | ||
Storage | 12,000 m | |||
EMC | EN 61326-1:2006 | |||
Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
Ingress Protection (IP) rating | IP42 | |||
Pollution Degree | 2 | |||
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
Weight | .22 kg (8 oz) | |||
Warranty | Three years |