$524

This Kit is built for preventative maintenance. This kit brings together the Fluke 1587FC Insulation Multimeter, Fluke i400 Current Clamp, and Fluke 62 MAX+ IR Thermometer. All units come with calibration certificate.

SKU: 1587KIT/62MAX+ FC-NIST Category:

Description

Fluke 1587/ET/62MAX+FC-NIST Offers

FLUKE 1587FC-NIST Insulation Meter

PI/DAR timed ratio tests (1587 FC only)
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
VFD low-pass filter for accurate motor drive measurements (1587?FC only)
Auto-discharge of capacitive voltage for added user protection
Insulation test (1587 FC: 0.01 M? to 2 G?) (1577: 0.1 M? to 600?M?)
Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (?), Continuity
Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Rugged, utility hard case allows you to bring everything you need for the job
Large display with backlight
Comes with Certificate of Calibration

FLUKE I400-NIST Current Clamp

Use with your Fluke 1587 to measure 1A AC to 400 A AC
1 mA/Amp output guarantees easy reading
CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
Specially designed to offer maximum utility in a very compact shape
Maximum conductor: 32 mm
Complete specifications
Comes with Certificate of Calibration

FLUKE 62max+-NIST Mini IR Thermometer

Quick and reliable surface temperature readings (non-contact)
Best accuracy in its class : + 1 % of reading or +1 ?C (+2 ?F)
Wide temperature range: -30? to 650 ?C (-22 ? to 1202 ?F)
Dual displays shows current and max measurements simultaneously
Holds temperature readings for 7 seconds
Comes with Certificate of Calibration

Fluke 1587 FC-NIST SpecificationsSpecificationsVoltage DCMaximum Voltage1000 VAccuracy?(0.09%+2))Maximum Resolution0.001VVoltage ACMaximum Voltage1000 VAccuracy?(2%+3)AC Bandwidth5kHz*
*with low pass filter; 3db @ 800 HzMaximum Resolution0.1 mVCurrent DCMaximum Amps400mAAmps Accuracy ?(0.2%+2)Maximum Resolution0.01 mACurrent ACMaximum Amps400mAAmps Accuracy1587: ?(1.5%+2)** 1kHz bandwidthMaximum Resolution0.01 mAResistanceMaximum Resistance50 M?Accuracy?(0.9%+2)Maximum Resolution0.1?CapacitanceMaximum Capacitance9,999 ?FAccuracy?(1.2%+2)Maximum Resolution1 nFFrequency
Maximum Frequency100 kHzAccuracy?(0.1%+1)Maximum Resolution0.01 HzTemperature Measurement

-40.0 ?C to 537 ?C
-40.0 ?F to 998 ?F
excluding probeDiode Test
Range6 VResolution1 mVAccuracy?(2 % + 1)Insulation TestMinimum Test Current @ 1k?/V
1mATest Voltages50, 100, 250, 500, 1000 VMaximum Resistance per Test Voltage50V
100V
250V
500V
1000V 2 G?Maximum Resolution per Test Voltage50V0.01 M?100V0.01 M?250V0.1 M?500V0.1 M?1000V0.1 M?Accuracy per Test Voltage50V?(3 % + 5)100V?(3 % + 5)250V?(1.5 % + 5)500V?(1.5 % + 5)1000V?(1.5 % + 5) to 600 M?, ?(10 % + 3) above 600 M?Environmental SpecificationsOperating temperature
-20 ?C to +55 ?CStorage temperature
-40?C to +60?CHumidity (Without Condensation)
0% – 95% (10 ?C – 30 ?C)
0% – 75% (30 ?C – 40 ?C)
0% – 40% (40 ?C – 55 ?C)Operating Altitude
2000 mSafety SpecificationsOvervoltage category
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 VAgency Approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 VMechanical & General SpecificationsSize
203 x 100 x 50 mm (with holster)Weight
624 gWarranty
3 yearsBattery life AlkalineMeter use1000 hoursInsulation test useMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M? with a duty cycle of 5 seconds on and 25 seconds off.IP Rating
IP40Fluke 62 MAX+ SpecificationsSpecificationsTemperature RangeFluke 62 MAX -30 ?C to 500 ?C (-22 ?F to 932 ?F)Fluke 62+ MAX -30 ?C to 650 ?C (-22 ?F to 1202 ?F)AccuracyFluke 62 MAX ?1.5 ?C or ?1.5% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Fluke 62+ MAX ?1.0 ?C or ?1.0% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Response Time (95%)Fluke 62 MAX <500 ms (95% of reading)Fluke 62+ MAX <300 ms (95% of reading)Spectral Response 8 to 14 micronsEmissivity 0.10 to 1.00Optical ResolutionFluke 62 MAX 10:1 (calculated at 90% energy)Fluke 62+ MAX 12:1 (calculated at 90% energy)Display Resolution 0.1 ?C (0.2 ?F)Repeatability of ReadingsFluke 62 MAX ?0.8% of reading or Click here for complete specifications on the Fluke 1587KIT/62MAX+ FC-NIST