Description
Fluke 1587/ET/62MAX+ FC Offers
FLUKE 1587 FC Insulation Meter
PI/DAR timed ratio tests (1587 FC only)
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
VFD low-pass filter for accurate motor drive measurements (1587?FC only) Filter for motor drive measurements
Insulation test (0.01M? to 2G?)
Insulation test voltages (50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
FLUKE I400 Current Clamp
Use with your Fluke 1587 to measure 1A AC to 400 A AC
1 mA/Amp output guarantees easy reading
CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
Specially designed to offer maximum utility in a very compact shape
Maximum conductor: 32 mm
Complete specifications
FLUKE 62max+ Mini IR Thermometer
Quick and reliable surface temperature readings (non-contact)
Best accuracy in its class : + 1 % of reading or +1 ?C (+2 ?F)
Wide temperature range: -30? to 650 ?C (-22 ? to 1202 ?F)
Dual displays shows current and max measurements simultaneously
Holds temperature readings for 7 seconds
Fluke 1587 FC SpecificationsSpecificationsVoltage DCMaximum Voltage1000 VAccuracy?(0.09%+2))Maximum Resolution0.001VVoltage ACMaximum Voltage1000 VAccuracy?(2%+3)AC Bandwidth5kHz*
*with low pass filter; 3db @ 800 HzMaximum Resolution0.1 mVCurrent DCMaximum Amps400mAAmps Accuracy ?(0.2%+2)Maximum Resolution0.01 mACurrent ACMaximum Amps400mAAmps Accuracy1587: ?(1.5%+2)** 1kHz bandwidthMaximum Resolution0.01 mAResistanceMaximum Resistance50 M?Accuracy?(0.9%+2)Maximum Resolution0.1?CapacitanceMaximum Capacitance9,999 ?FAccuracy?(1.2%+2)Maximum Resolution1 nFFrequency
Maximum Frequency100 kHzAccuracy?(0.1%+1)Maximum Resolution0.01 HzTemperature Measurement
-40.0 ?C to 537 ?C
-40.0 ?F to 998 ?F
excluding probeDiode Test
Range6 VResolution1 mVAccuracy?(2 % + 1)Insulation TestMinimum Test Current @ 1k?/V
1mATest Voltages50, 100, 250, 500, 1000 VMaximum Resistance per Test Voltage50V
100V
250V
500V
1000V 2 G?Maximum Resolution per Test Voltage50V0.01 M?100V0.01 M?250V0.1 M?500V0.1 M?1000V0.1 M?Accuracy per Test Voltage50V?(3 % + 5)100V?(3 % + 5)250V?(1.5 % + 5)500V?(1.5 % + 5)1000V?(1.5 % + 5) to 600 M?, ?(10 % + 3) above 600 M?Environmental SpecificationsOperating temperature
-20 ?C to +55 ?CStorage temperature
-40?C to +60?CHumidity (Without Condensation)
0% – 95% (10 ?C – 30 ?C)
0% – 75% (30 ?C – 40 ?C)
0% – 40% (40 ?C – 55 ?C)Operating Altitude
2000 mSafety SpecificationsOvervoltage category
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 VAgency Approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 VMechanical & General SpecificationsSize
203 x 100 x 50 mm (with holster)Weight
624 gWarranty
3 yearsBattery life AlkalineMeter use1000 hoursInsulation test useMeter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M? with a duty cycle of 5 seconds on and 25 seconds off.IP Rating
IP40Fluke 62 MAX+ SpecificationsSpecificationsTemperature RangeFluke 62 MAX -30 ?C to 500 ?C (-22 ?F to 932 ?F)Fluke 62+ MAX -30 ?C to 650 ?C (-22 ?F to 1202 ?F)AccuracyFluke 62 MAX ?1.5 ?C or ?1.5% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Fluke 62+ MAX ?1.0 ?C or ?1.0% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Response Time (95%)Fluke 62 MAX <500 ms (95% of reading)Fluke 62+ MAX <300 ms (95% of reading)Spectral Response 8 to 14 micronsEmissivity 0.10 to 1.00Optical ResolutionFluke 62 MAX 10:1 (calculated at 90% energy)Fluke 62+ MAX 12:1 (calculated at 90% energy)Display Resolution 0.1 ?C (0.2 ?F)Repeatability of ReadingsFluke 62 MAX ?0.8% of reading or Click here for complete specifications on the Fluke 1587KIT/62MAX+ FC