Fluke 125B Offers
Features
Dual-input digital oscilloscope and multimeter
Increased resolution and work load coverage with 40 MHz oscilloscope bandwidth
Two 5,000-count true-rms digital multimeters
Connect-and-View? trigger simplicity for hands-off operation; IntellaSet? technology automatically and intelligently adjusts numerical readout
Dual-input waveform and meter reading recorder for trending data over extended periods
Recorder Event Detect captures elusive intermittent signals
WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect? mobile app*
FlukeView? ScopeMeter? Software for Windows?
Check Industrial networks with BusHealth physical layer tests against defined reference levels
Single Phase Power Quality and Harmonics Analzyer
Applications
Automation & Process Control
Industrial
Maintenance & Repair
Motor Drive & Control
Test & Measurement
Automobile
Utility
HVAC
Elevator
Fluke 125B Specifications
DC Voltage Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy
? (0.5 % +5 counts)
True-rms Voltages (V ac and V ac+dc) Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5 % to 100 % of range (AC or dc coupled)
60 Hz to 20 kHz | ? (2.5 % +15 counts)
Frequency Response – DC Coupled
Without probes and test leads (with BB120)
dc to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads
DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
with VP41 10:1 Probe
dc to 40 MHz (-3 dB)
Frequency Response – AC Coupled (If roll off)
Without probes and test leads
<10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads
<10 Hz (-3 dB)
With VP41 10:1 Probe
<10 Hz (-3 dB)
Rise time, excluding probes, test leads
<17.5 ns
Power Quality
Readings
Watt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto)
250 W to 250 MW, 625 MW, 1.56 GW
Number of Harmonics
DC to 51
Bus health tester
AS-i
NEN-EN50295
CAN
ISO-11898
RS-232
EIA-232
RS-485
EIA-485