Fluke 115C/Fluke115C Field Multimeter 1000uF Backlight F115C Brand new original goods F-115C.

$113

Category:

Description

Specifications :
Maximum voltage between any terminal and earth ground :600 V
Surge protection : 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display: Digital: 6,000 counts, updates 4 per second
Bar graph : 33 segments, updates 32 per second
Operating Temperature : -10 °C to + 50 °C
Storage Temperature : -40 °C to + 60 °C
Battery type : 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life : 400 hours typical, without backlight

Accuracy Specifications :
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy:± ([% of reading] + [counts]):0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)

Continuity
Range: 600 O
Resolution: 1 O
Accuracy: Beeper on less than 20 O, off more than 250 O; detectsopens or shorts of 500 µs or longer.

Ohms
Range/Resolution: 600.0 O / 0.1 O
Range/Resolution: 6.000 kO / 0.001 kO
Range/Resolution: 60.00 kO / 0.01 kO
Range/Resolution: 600.0 kO / 0.1 kO
Range/Resolution: 6.000 MO / 0.001 MO
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MO / 0.01 MO
Accuracy: 5 % + 2

Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2

Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution 10.00µF /0.01µF
Range/Resolution: 100.0 µF / 0.1µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to1000µF
Accuracy: 1.9% + 2
Range/Resolution: more than 1000 µF
Accuracy: 5% + 20%

Lo-Z Capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical

AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A /0.001A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30-seconds max

DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30 seconds max

Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2

Reviews

There are no reviews yet.

Be the first to review “Fluke 115C/Fluke115C Field Multimeter 1000uF Backlight F115C Brand new original goods F-115C.”

Your email address will not be published. Required fields are marked *