Description
DESCRIPTIONS:
Ultrasonic device for detecting defects in metal, plastic and other homogeneous materials
Certificates for SiteScan flaw detector:
— The ultrasonic flaw detector SiteScan 123W, SiteScan 150S and SiteScan 250S is simple and easy to use, certified by the State Standard of Russia, registered in the State Register of Measuring Instruments and approved for use in the Russian Federation.
Warranty for flaw detectors SiteScan 123W, SiteScan 150S and SiteScan 250S: 24 months.
SiteScan flaw detector
Flaw detectors of the SiteScan series provide the implementation of standard and specialized methods of ultrasonic testing of welds, allows performing ultrasonic thickness gauging and flaw detection of a wide class of products, searching for places of corrosion, cracks, internal delaminations and other types of defects.
The most typical areas of application of the devices are NDT of welded seams of pipelines, boilers, metal structures during production and operational control at oil and gas enterprises, in energy, transport, shipbuilding, and the aerospace industry.
Areas of application for SiteScan flaw detectors
-
SiteScan 123W Ultrasonic Flaw Detector (Basic Broadband)
Typical applications: NDT training schools, first echo thickness/corrosion measurements, welding testing, delamination testing, etc. -
SiteScan 150S Ultrasonic Flaw Detector (Wideband)
Typical Application: Weld, thickness/corrosion testing (1 echo and through coating with data logging). -
SiteScan 250S Ultrasonic Flaw Detector (Narrowband 1-10 MHz)
Typical Application: Weld, thickness/corrosion testing (1 echo and through coating with data logging).
defect sizing. The 123W has DAC sizing techniques. The use of integrated sizing software reduces analysis time and hence speeds inspection.
High Visibility Display
For any flaw detector the display is a crucial element. The Sitescan has a colour transflective TFT display as standard, providing high visibility at any light level. The choice of colours for menus and waveform display enhance clarity, with the LCD simulation mode giving direct sunlight readability. The TFT does not suffer the typical black out problems or temperature limitations of LCD giving full weather capability.
High Performance with Total Control
The Sitescan series delivers high performance and advanced features, yet our engineer’s experience in user interface design has ensured it’s easy and quick to use. The acknowledged ease of use of previous generation Sitescans has been enhanced with the menu navigation key and intuitive menu structure, providing easy access to functions.
Rugged Reliability
Sonatest’s reputation for robust design and proven reliability is an important aspect of flaw detector ownership. Down time is expensive and should be minimized to ensure maximum productivity. The Sitescan series is constructed to high standards using Xenoy plastics and sealed to IP67, giving excellent water resistance so it can withstand the tough environments in which operators work. The Sitescan comes with 2 years warranty, extendable to 5 years with Sonacover, supported by a worldwide service network.
Sitescan 123 Accessories
SDMS (Optional Sonatest Data Management Software)
This Windows based data management tool allows the user to interface a Sonatest digital flaw detector with a PC. The software uploads and downloads panel settings and A-Scans, which can also be copied and pasted into Word for customised reporting. Thickness readings can be transferred directly into Excel with the ability to produce charts for B & C-Scans, colour 3D mapping etc.
SPECIFICATIONS:
Flaw detector D10 | D20 | Flaw detector 123W | Flaw detector 150S | Flaw detector 250S | 350M | 380M | |
measurement range | |||||||
0-5mm to 0-5000mm | + | + | |||||
0-5mm to 0-10000mm | + | + | + | ||||
0-1mm to 0-20000mm | + | + | |||||
Ultrasonic speed | |||||||
1000-9999 m/s | + | + | + | + | + | ||
256-16000 m/s | + | + | |||||
Delay | |||||||
0-5000, in 0.05 mm increments | + | + | |||||
0-10000, in 0.05 mm increments | + | + | + | ||||
0-20000, in 0.05 mm increments | + | + | |||||
Sensitivity | |||||||
0-110dB in 0.5/1/2/6/10/14/20dB steps | + | + | + | + | + | ||
0-110dB in steps of 0.1/0.5/1/2/6/10/14/20dB | + | + | |||||
Pulse generator | |||||||
Fixed 200V peak | + | + | |||||
Fixed 200V rectangular | + | + | + | ||||
100-350V rectangular | + | ||||||
100-450V rectangular | + | ||||||
Pulse length | |||||||
Fixed 20 ns | + | + | |||||
Fixed 100 ns | + | + | |||||
30-250ns associated with filter | + | ||||||
Peak to 2000 ns | + | + | |||||
ActiveEdgeTM _ | Fixed | + | + | ||||
Contour setting | + | + | |||||
CPI | |||||||
35-500Hz | + | + | |||||
5-1000 Hz | + | + | + | ||||
5-5000Hz | + | + | |||||
Frequency bands | |||||||
Wideband 1-15 MHz (-3dB) | + | ||||||
Narrowband at 1/2.25/5 MHz | + | ||||||
Wideband 1-20 MHz (-6dB) | + | ||||||
Wideband 1-10 MHz (-6dB) | + | + | |||||
Narrowband at 1/2.25/5/10 MHz | + | ||||||
Wideband 1.5-15 MHz (-6dB) | + | ||||||
Narrowband at 0.5/1/2.25/5/10/15 MHz | + | + | |||||
Wideband 2-22 MHz (-6dB) | + | + | |||||
cutoff | |||||||
50% | + | + | + | + | + | ||
80% Linear | + | + | |||||
straightening | |||||||
full wave | + | ||||||
Full Wave, +HW, -HW RF | + | + | + | + | + | + | |
gates | |||||||
One strobe | + | + | + | ||||
Two gates | opt | opt | + | + | + | + | |
Measurement modes | |||||||
Ch. / amplitude of the signal in the strobe | + | + | + | + | + | + | + |
Trigonometric function | + | + | + | + | + | + | + |
EE | + | + | + | + | + | + | |
G1-G2 | opt | opt | + | + | + | ||
T-Min | + | + | + | + | + | + | + |
Units | |||||||
mm and inches | + | + | + | ||||
mm, inches & microseconds | + | + | + | + | |||
Setting memory | |||||||
100 | + | + | + | + | + | + | + |
A-scan memory | |||||||
800 | + | + | + | + | |||
5000 | + | + | |||||
Reference signal | + | + | + | + | + | + | |
Thickness memory | |||||||
5000 in A-scan memory | + | + | |||||
8000 in Block/Location/Number format or programmed sequence | + | + | + | + | |||
Auto-calibration | + | + | + | + | + | + | |
split screen view | + | + | + | + | + | ||
Choice of colors and grids | + | + | + | + | + | + | |
Instant reference signal | + | + | + | + | + | + | + |
Active peak | + | + | + | + | + | + | + |
Half way pointer | + | + | + | + | + | + | + |
Measurement methods: | |||||||
CSC (curved surface correction) | + | + | + | + | + | + | |
ARC (Amplitude-distance curve) | opt | opt | + | + | + | + | + |
Divided ARC | opt | opt | + | + | + | ||
TCG (Temporary Sensitivity Adjustment) | opt | + | + | + | |||
ARD (Amplitude-Distance-Diameter) | opt | opt | + | + | + | + | |
Divided ARD | opt | opt | + | + | + | ||
AWS (American Welding Institute) | opt | opt | + | + | + | + | + |
API (American Petroleum Institute) | opt | opt | + | + | + | + | |
AGC (automatic gain control) | + | + | + | + | + | + | |
BEA (back wall echo attenuator) | + | + | |||||
IFT (Immersion Surface Trigger) | + | ||||||
Exits | |||||||
Front panel USB | + | + | + | + | + | + | + |
Video | + | + | + | + | + | + | + |
RS232 | + | + | + | + | + | ||
Proportional Analog | + | + | + | + | |||
Synchronization | + | + | + | + | |||
B-Scan | opt | opt |