Sonatest Masterscan 700m

$9,768

Category:

Description

descriptions:

The Masterscan 700M offers the end user a high end narrowband flaw detector with a full VGA display, sync and proportional outputs, sync input and a Spike and Square pulser. Features like high levels of near surface resolution, penetrating power (450V pulser – square and spike) and excellent signal to noise ratio, can be added and upgrades performed in the working environment, reducing downtime and increasing working flexibility. The Masterscan 700M’s enclosure is constructed using impact resistant materials and is designed to meet IP67 standards, offering excellent water resistance and harsh conditions. Typical applications are Weld Fabrication, Corrosion Detection, Composite Inspection, Bond Testing, Forgings & Castings, Power Generation (including EMATS) and general UT inspection.

Features
  • Configurable on-board software
  • Customizable & intuitive menus
  • Split DAC/AVG
  • Angle measurement mode
  • Dryscan capability
  • Encoded B-Scan
  • A-Scan fade
  • 4GB on-board memory
  • USB interface for PC import/export
Specifications
Test Range: 0.04″ (0-1mm) up to 787″ (0-20,000mm) in steel at 19455f/s (5930m/s)
Velocity: 256 – 16000 m/s continuously variable
Probe: 0 to 1000 μs
Delay: 800″ (0-20,000m) in steel at 5930 m/s
Gain: 0 to 110dB adjustable in 0.1, 0.5, 1, 2, 6, 14 and 20dB steps
Test Modes: Pulse echo and transmit/receive. Single Crystal, Double Crystal and Pitch-Catch.
Damping: 50 and 400 Ohm damping selectable
Pulser: 100-450V – ve spike and square wave. Pulse Width from 30nS to 2500nS. Rise/Fall times <5nS into 50R load.
P.R.F: Adjustable 5Hz to 6kHz. External sync also available.
Screen Update Rate: 60Hz
Rectification: RF, Full wave, +ve half-wave and -ve half-wave
Frequency Range: 8 selectable filter bands

  1. 100kHz – 500kHz
  2. 200kHz – 800kHz
  3. 0.4MHz – 1.6MHz
  4. 1.4MHz – 3.0MHz
  5. 3.0MHz – 8.0MHz
  6. 7.0MHz – 15.0MHz
  7. 9.0MHz – 21.0MHz
  8. 1.6MHz – 33.0MHz (Wideband)
  9. Additional tuned low frequency pre-amp with Dryscan option.
System Linearity: Vertical = 0.5% Full Screen Height (FSH); Horizontal +/-0.2% Trace Full Screen Width (FSW)
Reject (Selectable): Up to 80% Linear reject (removes baseline noise without affecting indication amplitude) or Up to 50% Suppressive reject (increase zero offset and reduces amplitude of all echoes).
LED Warning when active.
Units: Metric (mm), inch (in) or microseconds
Display: Color Transflective VGA (640 x 480) TFT
Display Area: 4.57″ x 3.43″ (116.16 x 87.2mm)
A-Scan Area: 400 x 510 pixels (normal), 460 x 620 (FS).
Colors: 9 color options with variable brightness.
Gate Monitor: Two independent gates for measurement and monitoring. Start and width fully adjustable over the entire range of the instrument. Levels adjustable from 0% to 100%, positive or negative triggering on each gate with audible & visible alarms. Gate resolution is 5Ns.
Zoom: Expands range and delay to cover the area set by Gate 1 start & width controls.
AGC: Automatic Gain Control automatically sets the signal in Gate 1 to a level between 10% and 90% FSH, tolerance between 5% and 20%.
Contour: Trailing-Edge-slew-rate control to reduce half cycles in rectified modes. Selectable from one of 6 levels.
Waveform Smoothing: Select from

  1. None (both min and max values are displayed in the A-Scan)
  2. Fill (Min values set to baseline value, produces a solid A-Scan)
  3. Smooth (min values ignored, produces a clear outline A-Scan)
Persistence: Causes previous A-scans to “fade out” at a user-determined rate
Auto-Cal: Provides automatic calculation of velocity and probe zero from 2 reference echoes.
Reference Waveform: Displays a previously stored A-log in a color different from the active display, enabling a quick visual check of the differences.
Clock: Built in, battery-backed RTC keeps time and date. Visible on the status line, always stored with Panels, A-logs, etc.
Internal Memory: 4GB storage available for A-scans, panels, T-logs, B-logs, etc… 450,000 Panels, 200,000 A-Logs, 300,000 B-Charts, 440,000 T-Logs.
Active Peak Memory: Retains all A-scans on screen for echo-dynamic pattern analysis, with the active A-scan displayed in a separate color.
Notes: Alphanumeric labelling for panel stores, A-logs, B-logs, etc…
Display Freeze: Hold the current waveform on screen for off-line processing
Help Key: Shows software and hardware information
Language Support: Multiple languages are selectable from a list including: English, French, Spanish, Russian, Chinese (Modern). Others are available upon request.
Encoder Connection: D-Sub 15 connector
Video Output: Standard on 700M
Proportional Outputs: Available on 700M
External Sync: Available on 700M
USB Connection: Internal Storage shown as Memory Device.
Transducer Sockets: BNC or LEMO (factory option)
Power: Lithium Ion 14.4V battery pack. Typically 16 hours for Masterscan 700M. Indication of battery charge status. Recharge time 3-4 hrs. Battery can be charged separately. Mains pack optional.
Charger: 100-240 VAC, 50-60 Hz
Environmental: Designed to meet IP67
Temperature: Operating: 14°F – 131°F (-10°C – 55°C)
Storage: -40°F – 167°F (-40°C – 75°C)
Dimensions: 5.7″ x 10″ x 5.7″ (145 x 255 x 145mm)
Weight: 5.5 lbs. (2.2kg) with battery
Warranty: 2 year
Extended Warranty: Sonacover – extended 5 year warranty, including 4 calibrations.
Calibration Standard: EN12668-1:2010 (Detailed Specification available upon request).
Standards: Vibration to 514.5-5 Proc 1 Annex Fig 6
Shock 516.5 Proc 1 15g/6ms
Explosive atmospheres – MIL-STD 810G
Method 511.5 Procedure 1