Description
Product Details and Specifications for TRIMBLE M1 Total Station
Selling the Trimble M1 Total Station, which is used for measurements and collecting survey data, but can also be used to determine design positions. This device has the ability to record and collect data from distance and angle measurements on a recording device, which can later be processed using computer software at the end of the survey.
- Angle accuracy of 2″ and 5″.
- Prisms and DR measurements.
- EDM which produces fast, accurate and reliable measurements.
- Long battery life with Li-Ion battery.
- Easy to use because there is a keypad.
- Sturdy and lightweight design.
The following are the specifications of the Trimble M1 Total Station
ANGLE MEASUREMENT | |
ISO 17123-3 accuracy (horizontal and vertical) | 2″/0.6 mgon
5″/1.5 mgon |
Reading system | Photoelectric detection by encoder |
Circle diameter | 88 mm (3.46 in) |
Horizontal angle | 2: Diametrical
5″: Single |
Vertical angle | Single |
Minimum Difference (degree, Gon, MIL6400) | 1/5/10″ – degrees
0.2/1/2 mgon – hinge 0.005/0.02/0.05 thousand – MIL6400 |
TELESCOPE | |
Tube length | 125 mm (4.9 in) |
Picture | Upright |
Enlargement | 30× (18x/36x with eyepiece) |
Effective diameter of the objective | 45 mm (1,8 in) |
Diameter EDM | 50 mm (1.97 in) |
Field of view | 1° 20′ |
Power completion | 3″ |
Minimum focus distance | 1,5 m (4,9 ft) |
Laser pointer | Red |
TILT SENSOR | |
Type | Single-axis |
Method | Liquid electricity detection |
Range switching | ± 3 |
Accuracy settings | 1” |
GENERAL SPECIFICATIONS | |
Resource | Li–ion battery |
Output voltage | 3.8 V DC |
Measurement time | For 11 hours (distance/angle measurement every 30 seconds)
For 22 hours (continuous angle measurement) |
Charging time, full charge | 4 hours |
Optical image degradation | Upright |
Enlargement | 3x |
Field of view | 5° |
Focus range | 0.5 m (1.6 ft) |
Display | 2″ backlight, graphic LCD (128 × 64 pixels;)
5 “Single Side, backlight, LCD grafis (128×64 pixel) |
Memory | 10.000 data |
Size (W x D x H) | 168 mm x 173 mm x 355 mm
(6.6 in x 6.8 in x 13.1 in) |
Heavy | Main unit (without battery) 4.9 kg (10.8 lb)
BC-65 Battery 0.1 kg (0.2 lb) Carrying case 2.5 kg (5.5 lb) Dual charger and AC adapter 0.6 kg (1.3 lb) |
ENVIRONMENT | |
Temperature range | -20°C – 50°C (-4°F – 122°F) |
Temperature range | -40°C – 60°C (-40°F – 140°F) |
Air pressure | 400 mmHg – 999 mmHg / hPa 533 – 1332 hPa / 15,8 inHg – 39,3 inHg |
Dust and water protection | IP54 |