Description
Fluke 414D-NIST Offers
Measures up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
Features
Tripod mode allows you to mount to a tripod for measuring long distances
Stake out function
Enhanced Pythagoras calculation for determining distance indirectly from three other measurements
Audible keypad feedback
Storage of the last twenty measurements for quick recall of distance
Strong environmental protection with IP54 (water spray and dust proof) sealing
The most advanced laser technology for distance measurement
Instant measurement with one-button operation
Easy targeting with bright laser
Quick calculation of area (square footage) and volume
Easy addition and subtraction of measurements
Minimum/maximum function
Improved battery life from automatic shut-off feature
Pythagoras calculation for determining distance indirectly from two other measurements
Pouch with Fluke logo
Fluke 414D-NIST Specifications
414D419D424DDistance Measurement Typical Measuring Tolerance[1] ? 2.0 mm [3]? 1.0 mm [3] Maximum Measuring Tolerance[2] ? 3.0 mm [3] ? 2.0 mm [3] Range at Leica target plate GZM26 50 m / 165 ft80 m / 260 ft100 m / 330 ft Typical Range[1] 40 m / 130 ft80 m / 260 ft80 m / 260 ftRange at unfavorable condition[4] 35 m / 115 ft60 m / 195 ft60 m / 195 ftSmallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
(10 / 50 / 100 m) ? laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m) 6 /30 / 60 mm
(10 / 50 / 100 m) Tilt measurement Measuring tolerance to laser beam[5] No No ? 0.2? Measuring tolerance to housing[5] No No ? 0.2? Range No No 360? General Laser class 2 Laser type 635 nm, <1 mW Protection class IP40 IP54 Automatic laser off After 90 seconds Automatic power off after 180 seconds Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurementsUp to 5,000
measurements Size (H X W X L) 116mm Length
53mm Width
33mm Depth 127mm Length
56mm Width
33mm Depth 127mm Length
56mm Width
33mm Depth Weight (with batteries) 113 g 153 g 158 g Temperature range: Storage Operation -25 ?C to +70?C
(-13 ?F to +158 ?F)
0 ?C to +40 ?C
(32 ?F to +104 ?F) -25 ?C to +70?C
(-13 ?F to +158 ?F)
-10 ?C to +50 ?C
(14 ?F to +122 ?F) Calibration cycle Not applicable Not applicable Tilt and compass Maximum altitude 3000 m 3000 m 3000 m Maximum relative humidity 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II) EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010 [1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ?C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 ?C to +50 ?C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ?0.01? per degree up to ?45? in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ?0.1?.
Click here for complete specifications on the Fluke 414D-NIST
Reviews