The Ideal Kit for Temperature and Distance
The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/HVAC problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.
Included with this kit:
Fluke 414D Laser Distance Meter
Fluke 62 MAX+ IR Thermometer
Fluke 414D Description
Put the Fluke 414D on your tool belt and reach beyond the common tape measure – up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
Fluke 62 MAX+ Description
Small in size extremely accurate and very easy to use. IP54 rated for dust and water resistance.
Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX + infrared thermometers are everything you’d expect from the experts in measurement tools. Small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX + are so tough, they’re the only IR thermometers around you can handle without care.
If you’ve ever used an infrared thermometer, then you may have been fooled regarding the temperature reading. That’s because IR thermometers project a measurement cone at a surface and take the average temperature of the cone at the target. Although most IR thermometers have a laser pointer, a laser is a line, not a cone, and you may think that you’re getting temperature at the laser point only. Fluke’s 62 Max+ uses two rotating laser pointers that show you the size of the measurement area. It covers the temperature range from -30?C to 650?C with a response time less than 300 ms. The Model 62 Max uses a single laser pointer and covers the temperature range from -30?C to 500?C.
The Max 62 and Max 62+ are designed to withstand drops up to 3 m. Is screen is located in a position and with a viewing angle (15?) that, in many cases, lets you see the display without having to move the thermometer from the measuring point. For most measurements, you simply pull the trigger once you’ve identified the measurement point.
Why IR Thermometers?
Temperature is often the first indication of potential problems in electrical and mechanical applications. But how can you easily determine if an electrical panel has a hot spot, a motor is overheating or an HVAC system is inefficient? The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems.
Why Fluke 62 MAX and Fluke 62 MAX+?
Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX+ infrared thermometers are everything you’d expect from the experts in measurement tools: small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX+ are so tough, they’re the only IR thermometers around you can handle without care.
Fluke 414D Specification414D419D424DDistance Measurement Typical Measuring Tolerance[1] ? 2.0 mm [3]? 1.0 mm [3] Maximum Measuring Tolerance[2] ? 3.0 mm [3] ? 2.0 mm [3] Range at Leica target plate GZM26 50 m / 165 ft80 m / 260 ft100 m / 330 ft Typical Range[1] 40 m / 130 ft80 m / 260 ft80 m / 260 ftRange at unfavorable condition[4] 35 m / 115 ft60 m / 195 ft60 m / 195 ftSmallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
(10 / 50 / 100 m) ? laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m) 6 /30 / 60 mm
(10 / 50 / 100 m) Tilt measurement Measuring tolerance to laser beam[5] No No ? 0.2? Measuring tolerance to housing[5] No No ? 0.2? Range No No 360? General Laser class 2 Laser type 635 nm, <1 mW Protection class IP40 IP54Automatic laser off After 90 seconds Automatic power off after 180 seconds Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurementsUp to 5,000
measurements Size (H X W X L) 116mm Length
53mm Width
33mm Depth 127mm Length
56mm Width
33mm Depth 127mm Length
56mm Width
33mm Depth Weight (with batteries) 113 g 153 g 158 g Temperature range: Storage Operation -25 ?C to +70?C
(-13 ?F to +158 ?F)
0 ?C to +40 ?C
(32 ?F to +104 ?F) -25 ?C to +70?C
(-13 ?F to +158 ?F)
-10 ?C to +50 ?C
(14 ?F to +122 ?F) Calibration cycle Not applicable Not applicable Tilt and compassMaximum altitude 3000 m 3000 m 3000 m Maximum relative humidity 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) 85% at 20 ?F to 120?F
(-7 ?C to 50 ?C) Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II) EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010 [1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ?C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 ?C to +50 ?C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ?0.01? per degree up to ?45? in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ?0.1?.Fluke 62 MAX+ SpecificationsSpecificationsTemperature RangeFluke 62 MAX -30 ?C to 500 ?C (-22 ?F to 932 ?F)Fluke 62+ MAX -30 ?C to 650 ?C (-22 ?F to 1202 ?F)AccuracyFluke 62 MAX ?1.5 ?C or ?1.5% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Fluke 62+ MAX ?1.0 ?C or ?1.0% of reading, whichever is greater
-10 ?C to 0 ?C: ?2.0
-30 ?C to -10 ?C: ?3.0Response Time (95%)Fluke 62 MAX <500 ms (95% of reading)Fluke 62+ MAX <300 ms (95% of reading)Spectral Response 8 to 14 micronsEmissivity 0.10 to 1.00Optical ResolutionFluke 62 MAX 10:1 (calculated at 90% energy)Fluke 62+ MAX 12:1 (calculated at 90% energy)Display Resolution 0.1 ?C (0.2 ?F)Repeatability of ReadingsFluke 62 MAX ?0.8% of reading or Click here for complete specifications on the Fluke 414D/62-MAX+