Fluke 561 Offers
Lighten up your toolbox. This thermometer combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both infrared and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort.
Features
IR thermometer for quick measurements up close, or at a distance, without a ladder
Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
Single-point laser sighting
Temperature range of -40 to 1022?F (-40 to 550?C) covers most industrial and residential applications
Easy emissivity adjustment (Lo, Med, Hi) for measuring pipes and other shiny materials more accurately
Lightweight (just 12 ounces/340 grams) and portable
Very easy to use
Efficient ? no need to shut down equipment when making IR measurements
MIN, MAX, and DIF functions help you quickly identify problems
Applications
Electrical
HVAC
Industrial
Facilities Maintenance
Fluke 561 Specifications
Temperature Range
-40 to 1022?F (-40 to 550?C)
Display Resolution
0.1?F (0.1?C) of reading
D:S (Distance on Spot Size)
12:1
Easy Emissivity Selector
Adjustable with three settings Low (0.3), Medium (0.7). High (0.95)
Display Accuracy [Assumes ambient operating temperature of 73?F (23?C) to 77?F (25?C)]
?1.0% of reading ?1% of reading or ?2?F (?1?C), whichever is greater below 32?F/0?C, ?2?F (?1?C) ? 0.1?/1?
Response Time
500 mSec (95% of reading)
Repeatability
?0.5% of reading or ?2?F (?1?C), whichever is greater
Spectral Response
8 ?m to 14 ?m
Laser Sighting
Single point laser
Laser Shutoff
Laser turns off above ambient temperature of 104?F (40?C)
Laser Power
Class 2(II) operation; Output <1mW, wavelength 630-670 nm
Relative Humidity
10 to 90% RH non-condensing, at <86?F (30?C)
Power
2 x AA batteries (alkaline or NiCD)
Battery Life
12 hours
Display Hold
7 Seconds
Backlit Display
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options
Operating Temperature
32 to 120?F (0 to 50?C)
Storage Temperature
-25 to 150?F (-20 to 65?C)
MAX, MIN, DIF Temperatures
Yes
Thermocouple Type K Mini Adapter Input
Yes, compatible with industry standard K type probes with mini-connector.
Thermocouple Type K Velcro Pipe Probe
Yes, with a temperature range of 32 to 212?F (0 to 100?C) and accuracy of ?4?F (?2.2?C)
HVAC Measurement Guide
Yes
Click here for complete specifications on the Fluke 561
Reviews