The Fluke 3000 FC HVAC System provides measurement of all common electrical parameters

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000 V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:

  • True-RMS AC clamp meter
  • Measure up to 400 AAC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications: Fluke 3000 FC HVAC System

Fluke 3000 FC Series Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [Number of least significant digits]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mV Range / Resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / Resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / Resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 1.5% + 3
mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 1 0.1% + 1
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ Typical short circuit current
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

Fluke a3000 FC Wireless AC Current Clamp Module

Specifications
Range 0.5 A to 400.0 A
Resolution 0.1 A
Accuracy 400.0 A: 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100 Hz to 500 Hz)
Inrush Max displayed reading 999.9A
Crest factor (50 Hz / 60 Hz) 3 at 500 A
2.5 at 600 A
1.42 at 1000 A
add 2% for C.F. > 2
LCD w/ backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT III 600 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP30
Pollution Degree 2
Jaw opening 34 mm (1.33 in)
Size (H x W x D) 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in)
Weight .22 kg (8 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

Fluke t3000 FC Wireless K-Type Temperature Module

General Specifications
Range K-Type -200°C to 1372°C
Resolution 0.1°C
Accuracy ±[0.5% + 0.3°C] counts
Input terminals K-type mini
LCD w/backlight 3 ½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.01% of reading +0.03°C per°C
Temperature scale ITS-90
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, CAT I, 3rd edition Pollution Degree 2
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight .22 kg (8 oz)