Description
Fluke 289 CAL – True-RMS Data Logging Multimeter
Features
- Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and Fluke Connect mobile app)
- TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy
- Low pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment
- LoZ volts, low impedance voltage function for eliminating ghost voltages
- Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event
- Large 50,000 count, ¼ VGA dot matrix display with white backlight
- Logging function with expanded memory for unattended monitoring of signals over time
- Using on-board TrendCapture users can graphically review logged readings without needing a PC
- Store up to 15,000 recorded events
- Save multiple logging sessions before PC download is necessary
- Two terminal 50 Ω range with 1 MΩ resolution, 10 mA source current
- On board help screens for measurement functions
- Real time clock for automatic time stamping of saved readings
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- True RMS AC voltage and current for accurate measurements on non-linear signals
- Measure up to 10 A (20 A for 30 seconds)
- 100 mF capacitance range
- Peak capture to record transients as fast as 250 µs
- Works with optional FlukeView forms to enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
Applications
-
- Electronics
- Plant automation
- Power distribution
- Electro-mechanical equipment
Specifications:
DC Volts Range/Resolution 50.000 to 500.00 mV
5.0000 to 50.000 V
500.00 to 1000.0 VBasic Accuracy 0.025% AC Volts Range/Resolution 50.000 to 500.00 mV
5.0000 to 50.000 V
500.00 to 1000.0 VBasic Accuracy 0.4% (True RMS) DC Current Range/Resolution 500.00 to 5000.0 µA
50.000 to 400.00 mA
5.0000 to 10.000 ABasic Accuracy 0.05% AC Current Range/Resolution 500.00 to 5000.0 µA
50.000 to 400.00 mA
5.0000 to 10.000 ABasic Accuracy 0.6% (True RMS) Temperature (Excluding Probe) Range/Resolution 328 to 2462°F (-200 to 1350°C) Basic Accuracy 1.0% Resistance Range/Resolution 50.000 to 500.00 Ω
5.0000 to 50.000 kΩ
500.00 kΩ to 5.0000 MΩ
50.00 to 500.0 MΩBasic Accuracy 0.05% Capacitance Range/Resolution 1.000 to 10.00 nF
100.0 nF to 1.000 µF
10.00 to 100.0 µF
1000 µF to 100 mFBasic Accuracy 1.0% Frequency Range/Resolution 99.999 to 999.99 Hz
9.9999 to 999.99 kHzBasic Accuracy 0.005% General Specifications Maximum Voltage Between any Terminal and Earth Ground 1000 V Battery Type 6 x AA Alkaline batteries, NEDA 15A IECLR6 Battery Life 100 hours minimum, 200 hours in logging mode Operating Temperature -4 to 131°F (-20 to 55°C) Storage Temperature -40 to 140°F (-40 to 60°C) Relative Humidity 0 to 90% (32 to 98.6°F [0 to 37°C])
0 to 65% (98.6 to 113°F [37 to 45°C])
0 to 45% (113 to 131°F [45 to 55°C])Electromagnetic Compatibility EMC EN61326–1 Vibration Random vibration per MIL-PRF-28800F Class 2 Shock 3.3 (1 m) drop per IEC/EN 61010–1 3rd Edition Dimensions 8.75 x 4.03 x 2.38″ (222 x 102 x 60 mm) Weight 1.92 lbs (870.9 g)
Reviews