Description
Fluke 719PRO-30G Offers
Features
Electric pump for one handed pressure calibration
Best in class pressure measurement uncertainty of 0.025%
Measure and source mA with best in class 0.015% accuracy
Precision pressure adjust vernier for accurate pressure calibration
Variable release rate bleed valve for easy pressure adjustment
Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
Display backlight
Damping, Min/Max, and % error function
Source mA with simultaneous pressure measurement to test valves and I/Ps
Simulate mA signals to troubleshoot 4-20 mA loops
Test pressure switches with built in switch test function
Power transmitters during test using 24 V loop supply with simultaneous mA measurement
Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
Proven cleanout ports reduce pump failures
Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
Pressure Instrument CalibrationPressure Instrument MaintenancePetro-ChemicalOil and GasPharmaceuticalWater and wastewaterFood and BeveragePower Generation
Fluke 719Pro Specifications
Pressure
Range
-12 to 300 PSI / -0.8 to 20 bar
Resolution
0.01 PSI, 0.001 bar
Accuracy
? 0.025 % of full scale, 6 months ? 0.035 % of full scale, 1 year Dry Air and non-corrosive gas only
Temperature Effect
(all ranges)
Add ? 0.002 % F.S./?C for temps outside of 15 to 35?C
No effect on accuracy on all functions from 15 to 35?C
mA DC (simulation and measurement)
Range
0-24 mA DC
Resolution
0.001 mA
Accuracy
? 0.015 % of reading ? 2 counts
Max load in mA source
1000 ohm
Max? voltage in mA simulate
26 V DC
Volts DC (measurement only)
Range
30 V DC
Resolution
0.001 V
Accuracy
? 0.015 % of reading ? 2 counts
Notes
No AC voltage measurement, do not exceed 30V DC
Temperature (measurement only, Pt100 RTD)
Range
-50 to 150 ?C (-50 to 302?F)
Resolution
0.01 to 0.01?F
Accuracy
? 0.1?C (0.2?F)
Loop power supply
Range
24 V DC
Accuracy
24 mA at 24 V
Temperature Effect (all functions)
Accuracy
Add ? 0.002 % F.S./?C for temps outside of 15 to 35?C
No effect on accuracy on all functions from 15 to 35?C
Connections
Pressure
1/8 inch female NPT
Electrical
Standard banana jacks
RTD
4 pin miniature circular
External module
6 pin miniature circular
Power Requirements
Battery
Eight (8) standard Alkaline AA batteries
Battery life
300 pump cycles to 150 PSI minimum; 1000 pump cycles to 30 PSI; 100 pump cycles to 300 PSI minimum
Physical
Dimensions (HxWxD)
24.13 cm x 11.18 cm x 7 cm (9.5 in x 4.4 in x 2.8 in)
Weight
With holster 1.2 kg (2.5 lb)
Reviews